llms.txt
Search Documentation
Search through all documentation pages
v4.x

v4.2.2 Changelog

See what's new in Kener v4.2.2, where events that affect only hidden monitors stay off the public site

Release date: November 19, 2026

Important

Upgrade if you use hidden monitors. Before v4.2.2, an incident or maintenance that affected only hidden monitors was public on the events page, in /rss.xml, and on its own incident or maintenance page. See Events of hidden monitors.

Security

Events of hidden monitors were public

Field Value
Affected versions v4.2.1 and earlier
Fixed in v4.2.2
Severity Medium, CVSS 3.1 score 5.3 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N)
Weakness CWE-862 (Missing Authorization)

A hidden monitor has is_hidden = YES. A global event (is_global = YES) shows on every status page, whatever monitors it affects. New incidents and maintenances are global by default.

Before v4.2.2, Kener removed hidden monitors from the affected monitors that the incident or maintenance page shows. The event itself stayed public. So a non-global incident or maintenance that affected only hidden monitors showed its title, description, and comments in these places:

  • The events page, for example /events/November-2026.
  • The RSS feed at /rss.xml.
  • The incident page /incidents/{id} and the maintenance page /maintenances/{id}.

Kener now shows an event in these places only when the event is global or affects a monitor that is not hidden. When an event is not global and affects only hidden monitors, its incident or maintenance page returns 404. A signed-in user whose role has monitors.read sees hidden monitors, so that user can still open the page of an event that affects only hidden monitors. See Monitor Visibility.

The same rule applies to a non-global event that has no affected monitors, for example because you deleted its monitors. Before v4.2.2 such an event was public too. It is now left off these lists and pages.

What to do:

  1. Upgrade to v4.2.2.
  2. In Manage → Incidents and Manage → Maintenances, find each event that has Global Incident or Global Maintenance turned off and that affects only hidden monitors or no monitors. Include an event that matched before you edited it, for example an event that you later made global or linked to a visible monitor.
  3. If one of these events named a host, a password, or another private detail, treat that detail as public. Change any secret it named, and edit the event to remove the detail. Check what the event said before your edits too. Feed readers may keep the copy of /rss.xml that they already fetched, and you cannot remove it, so changing the secret is the only fix.